So sánh sản phẩm
chọn tối đa 4 sản phẩm

CANopen, 3-phase power meter (400 A)

CANopen, 3-phase power meter (400 A)

Hãy trở thành người đầu tiên đánh giá sản phẩm này( 0)
  • Lượt xem: 3088
  • Ngày đăng: 04/02/2016
Giá sản phẩm0
Mã sản phẩmPM-3133-400P-CPS
PM-3133
3-Phase Smart Power Meter
 
 
Model: PM-3133
 
  • True RMS Power Measurements
  • Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
  • Current Measurements Up to 400 A with Different CT Ratio
  • Voltage Measurements Up to 500 V
  • Clip-on CT for Easy Installation
  • W Accuracy Better than 0.5% (PF=1)
  • Supports RS-485, Ethernet (PoE) or CANopen Interface
  • Supports Modbus RTU, Modbus TCP or CANopen Protocol
  • Supports 2 Power Relay Output (Form A)
  • Total Harmonic Distortion (THD)
 
ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for three-phase power measurement. With its high accuracy (<0.5%, PF=1 ), the PM-3000 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 400 A). It operates over a wide input voltages range 10 ~ 500 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CANopen protocols for easy integration.
 
Model PM-3133 PM-3133-MTCP PM-3133-CPS
AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Input Voltage 10 ~ 500 V
Input Current CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A); CTØ36 mm (300 A); CTØ36 mm (400 A)
Input Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
Communication
RS-485 Protocol Modbus-RTU - -
Baud rate 9600,19200 (default), 38400, 115200;
DIP Switch Selectable
- -
Data format N,8,1 - -
Isolation 2500 VDC - -
Ethernet (PoE) Protocol - Modbus TCP -
CANopen Protocol - - CAN and CANopen
Baud rate - - 125 k (default), 250 k, 500 k,
1 M; DIP Switch Selectable
Isolation - - 2500 VDC
Alarm Output
Power Relay Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Power
Input Range +12 ~ 48 VDC
Power Consumption 4 W
Mechanical
Casing Plastic
Dimensions (W x L x H) 127 mm x 105 mm x 33 mm
Module Installation DIN-Rail Mounting
CT Installation Clip-On
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Ambient Relative Humidity 10% ~ 90% RH, Non-condensing
 
RS-485 Interface
PM-3133-100 Modbus RTU, 3-phase power meter (60 A)
PM-3133-160 Modbus RTU, 3-phase power meter (100 A)
PM-3133-240 Modbus RTU, 3-phase power meter (200 A)
PM-3133-360P Modbus RTU, 3-phase power meter (300 A)
PM-3133-400P Modbus RTU, 3-phase power meter (400 A)
Ethernet Interface
PM-3133-100-MTCP Modbus TCP, 3-phase power meter (60 A)
PM-3133-160-MTCP Modbus TCP, 3-phase power meter (100 A)
PM-3133-240-MTCP Modbus TCP, 3-phase power meter (200 A)
PM-3133-360P-MTCP Modbus TCP, 3-phase power meter (300 A)
PM-3133-400P-MTCP Modbus TCP, 3-phase power meter (400 A)
CANopen Interface
PM-3133-100-CPS CANopen, 3-phase power meter (60 A)
PM-3133-160-CPS CANopen, 3-phase power meter (100 A)
PM-3133-240-CPS CANopen, 3-phase power meter (200 A)
PM-3133-360P-CPS CANopen, 3-phase power meter (300 A)
PM-3133-400P-CPS CANopen, 3-phase power meter (400 A)
Tags: